2019-11-20How to check the flatness of tempered glass?
The flatness of tempered glass is mainly characterized by two technical indicators: overall bow and Local bow.Overall bow: Place a ruler against two edges of the glass or in diagonal direction and use a feeler to measure the gap between the straight
-
2019-10-16Why is it difficult to temper the borosilicate fire-resistant glass?
As the borosilicate fire-resistant glass has a high softening point and very low coefficient of thermal expansion, it creates a big challenge to tempering process.
-
2019-09-18How to inspect the uniformity of the cooling air pressure in the chiller …
Use an electronic micro compressor with level 1 accuracy to measure the air pressure of the chiller and take the average of the 4 measuring spots to compare with the maximum and minimum values.
-
2019-08-13How does the LandGlass reverse bending glass tempering furnace work?
When the glass tempering furnace makes reverse bending, it uses the T plates engaged with each other, stop blocks, and drive device in the special variable curvature mechanism to control the roller curvature of the soft shaft.
-
2019-07-18What is the Universal Chiller of LandGlass’ E curvature glass temper…
The Universal Chillers of LandGlass’ E curvature glass tempering furnace consists of several independent chillers.
-
2019-06-25What is the effect of the flatness of tempered glass on the finished glass…
Poor flatness and uneven thickness of tempered glass will cause optical distortion. In addition, it may cause excessive partial thickness which makes the installation more difficult.
-
2019-05-31What is the structure of the main driving system and its working princip…
What is the structure of the main driving system and its working principle?
-
2019-04-25How is intelligent tempering realized in the glass tempering furnace to …
The glass tempering furnace controlling system will automatically identify the tempering stage and adjust the air blowing pressure accordingly to reduce the unnecessary high load run.