Technical Data
-
2018-10-22What are the main structural components of LandGlass’ C-bent glass te…
The C-bent section of LandGlass’ C-bent glass tempering furnace employs a fully integrated welding rack. The main components comprise of a cooling system, a drive system, a servo controlled bending system and an air control system.
-
2018-09-19What defects usually occur during the early stage of glass heating in th…
At this point, the speed of the convectional blowers in the upper section of the glass tempering machine should be properly increased or the upper and lower furnace temperature should be adjusted accordingly, allowing the glass to be rapidly flattene
-
2018-08-08How do you dismantle the ceramic rollers in the glass tempering furnace…
Only when the glass tempering furnace has been completely cooled before you can change the ceramic rollers in the tempering furnace.
-
2018-07-12How do you clean up the ceramic rollers in the glass tempering furnace?
Use a vacuum cleaner to remove the surface powdery dust on the ceramic rollers in the glass tempering furnace.
-
2018-06-12What is the seamless input/output processing control in the glass temperi…
What is the seamless input/output processing control in the glass tempering furnaces? It refers to the processing control over the heating chamber to allow input and output simultaneously.
-
2018-05-17How does a proximity switch work?
A proximity switch is a type of position limit switch that operates without any direct physical contact with moving parts.
-
2018-04-19How does a position limit switch work?
Also known as limit switch, it is a type of low current electric command device often used for position detection control.
-
2018-03-28What should we do if white haze occurs during glass temping process?
What should we do if white haze occurs during glass temping process? Check the equipment’s leve; Check for the radial runout of the ceramic roller bed; and Appropriately switch on a higher heat balance pressure and operating time.